  1. Wiring size for 75-foot run from 40 amp breakers to tankless water ...

    Nov 2, 2020 · What type of wire will I need to use for a long run from my 40 amp breakers? Heater will be 240v and about 50-55 feet from the panel. I'm doing the ceiling remodel and adding …

  2. What Wire Should be Used for a 40A 240V Circuit?

    Given a 240V 40A circuit is there an official wire type that should be used? I assume there is a building code standard for this somewhere, but I don't really know where to look.

  3. breaker size, wire gauge, and minimum circuit ampacity (MCA)

    Jun 6, 2024 · But I'm good with 8awg/40-amps EVEN if I up-rate the larger heater (125%*4500 + 3500)/240, so seems ok. And it seems like sticking with a 40-amp breaker on 8awg NM-B …

  4. What size breaker & wire do I need for my mini-split installation?

    Oct 24, 2023 · All wires need to be the minimum size for the breaker. You must use 8 gauge on a 40 amp breaker, no smaller. If the disconnect is fused at 30 amps then you could use 10 …

  5. electrical - Is 40-amp breaker enough for my new range? - Home ...

    Jul 11, 2014 · 3 My new range says it needs a 40-amp circuit breaker minimum. But it also says maximum draw is 13,200 watts on 120/240, so doesn't that mean a 40-amp breaker would be …

  6. electrical - Is a 40 amp breaker acceptable to use for an induction ...

    Mar 30, 2025 · The breaker size protects the wire/cable from over heating/catching fire. It is always bad to increase breaker size without checking the wire size/gauge is correct for the …

  7. kitchens - Wiring for new 40 amp wall oven and cooktop - Home ...

    Aug 10, 2019 · The old units were rated for 30 amps each and the new units require 40 amps. We have a 200 amp main panel with one 40 amp breaker for the oven/cooktop that feeds 600 volt …

  8. electrical - Is a 40 amp breaker enough for my stove? - Home ...

    Mar 16, 2025 · The stove has five burners, convection, and air fryer. I currently have a 40 amp breaker for my 220 power outlet. Is this enough amps for 120/240 V;60 Hz 2N ~ 13 kW?

  9. Can a 40amp breaker be used safely and without issue with a …

    Jun 11, 2019 · 30 The breaker needs to be sized to protect the wire and the device. Wire Larger wire (which is a lower # due to the way wire sizes are named) can use a larger breaker. But a …

  10. wiring - What wire to use from main panel to subpanel - Home ...

    Jul 13, 2022 · I have a double pole 40 amp breaker that is available (or I can change it). 5 (3 subpanel is 33 feet away indoors. I will need 5 poles (spaces) in subpanel, and the total amps …